Vertiv OneCore là một giải pháp hạ tầng trung tâm dữ liệu (data center) lai (hybrid) được sản xuất sẵn. Nó được thiết kế để triển khai nhanh chóng và linh hoạt cho các trung tâm dữ liệu công suất lớn từ 5 MW trở lên, đặc biệt phù hợp với nhu cầu của các ứng dụng AI, tính toán hiệu suất cao (HPC) và mật độ cao.

Vertiv Onecore
0
Follow :
danh mục sản phẩm
Miền Bắc
Địa chỉ: Tổ 9 Đầm Sòi, Đầm Hồng, Phường Phương Liệt
Điện thoại: 0941531889
Miền Bắc
nội dung

Vertiv Power Skid

Placed on single skid frame, critical power infrastructure includes:

•   Vertiv UPS and Batteries

•   LV Switchboard

Perfect for installation within a dedicated single-space power room.

Vertiv PowerNexus

•   Close-coupled 1.5 – 2.5 MW Vertiv Trinergy UPS and Switchgear

•   Available in back-to-back or front-to-front configuration and suitable for integration either in a Module or on a Skid

•   Up to 50% reduction in installation time compared to traditional builds

•   Minimized interconnections reduce fault risks and simplify maintenance

•   Integrated design reduces footprint



Vertiv One Core design specifications

Design Specifications Unit Vertiv One Core Reference Design 1 Reference Design 2
General
Nominal IT load MW 5 to 50 single block 12.5 50
Power Supply 400V, 415V, 480V/ 3ph / 50, 60 Hz
Medium voltage (MV) KV 11, 13.8, 15, 20, 22, 24, 33, 35 24 24
Number of racks (1) 96 - 944 236 944
Cooling technology Chilled Water - CW Chilled Water - CW Chilled Water - CW
Separate circuits for Liquid cooling Optional Yes Yes
Heat rejection FIZ chiller for Air portion and TRIM cooler for Liquid portion
White space cooling type Perimeter CW Perimeter CW Perimeter CW
Coolant Distribution Unit (CDU) XDU600, XDU1350, XDU2300 XDU1350 XDU1350
Secondary fluid network Stainless steel, Copper, Plastic Stainless steel Stainless steel
Secondar Secondary fluid network coolant PG 25
Redundancy
Electrical redundancy Concurrently maintainable distributed redundancy Concurrently maintainable distributed redundancy Concurrently maintainable distributed redundancy
Compute rack feed 4 to make 3 2N 4 to make 3 4 to make 3
Networking and storage rack feed 2N 2N 2N
Thermal redundancy
Primary Fluid Network (PFN) N+1, 2N, Concurrently maintainable Concurrently maintainable Concurrently maintainable
Secondary Fluid Network (SFN) N+1 N+1 N+1
Back-up
Thermal min 2 - 5 3 3
Electrical min 1 - 10 5 5
Power Smoothing (2) % 0 - 100 0 0
Site
Site area (3) m2/ sq ft 6,600 / 71,100 26,100 / 281,000
Data hall (IT Hall) footprint m2/ sq ft 1,500 / 16,000 4 halls of 1,500 / 16,000
(6,000/ 64,000)
Deployment in phases No Yes
Outdoor Temperature Range °C / °F -20 to 55 / -4 to 131
(1) 600mm wide rack
(2) Active reduction of complex AI load profile
(3) Site area does not include space occupied by Diesel generators (Gensets)


Vertiv OneCore: reference designs

Vertiv  OneCore - Reference design 1

•   12.5 MW AI data center

•   Single Data Hall of 1,500 m2 / 16,000 sq ft

•   236 racks

•   Separate Primary Fluid Network (PFN) for Direct Liquid Cooling (DLC)

•   Air cooling / Liquid cooling ratio: 20% / 80%

•   Electrical redundancy: Concurrently maintainable distributed redundancy

•   Thermal redundancy:

-  SFN – N+1

-  PFN – Concurrently maintainable


Vertiv OneCore - Reference design 2

•     50MW AI data center

•     Single Data Hall of 1,500 m2 / 16,000 sq ft

•     944 racks

•     Separate Primary Fluid Network (PFN) for Direct Liquid Cooling (DLC)

•     Air cooling / Liquid cooling ratio: 20% / 80%

•     Electrical redundancy: Concurrently maintainable distributed redundancy

•     Thermal redundancy:

-  SFN – N+1

-  PFN – Concurrently maintainable

Vertiv PowerNexus

Vertiv Power Skid

Placed on single skid frame, critical power infrastructure includes:

•   Vertiv UPS and Batteries

•   LV Switchboard

Perfect for installation within a dedicated single-space power room.

Vertiv PowerNexus

•   Close-coupled 1.5 – 2.5 MW Vertiv™ Trinergy™ UPS and Switchgear

•   Available in back-to-back or front-to-front configuration and suitable for integration either in a Module or on a Skid

•   Up to 50% reduction in installation time compared to traditional builds

•   Minimized interconnections reduce fault risks and simplify maintenance

•   Integrated design reduces footprint


Vertiv cooling modules and skids

Vertiv Cooling modules or skids are prefabricated structures incorporating a range of Vertiv cooling units that enables ideal operational climate conditions within the data center IT hall, and also serves as a standalone mechanical corridor block, enabling full serviceability. These solutions typically include perimeter cooling units and, for AI applications, the Vertiv CoolChip coolant distribution unit, as well as necessary piping, both for primary and secondary fluid network. External primary fluid network piping can be featured in a separate piping skid, offering turn-key piping system delivered with verified cleanliness.

Prefabricated cooling skids are engineered for seamless integration within Vertiv OneCore, allowing them to be effortlessly installed into the completed building structural framework.


Vertiv SmartRun - IT superstructure

Vertiv SmartRun, as Vertiv OneCore key feature, delivers prefabricated data center data hall overhead infrastructure solutions including busway, piping, network cabling, and aisle containment, expertly engineered to streamline deployment and maximize efficiency. By reducing installation times by up to seven times compared to traditional methods, and leveraging prefabricated assemblies from Vertiv’s global manufacturing facilities, Vertiv SmartRun enables scalable projects with minimal on-site labor for overhead infrastructure.

- Pre-sales phase:

•   Consulting with presales team during bidding stage

•   Deployment cost estimation and supervision planning

•   Identifying and contacting local partners across the world

- Design phase:

•   Consultation during schematic design (SD), detailed design (DD) and construction documentation (CD) phases

•   Integration of on-site experience into existing and new design solutions

- Factory assembly phase:

•   Consulting with factory team

•   Monitoring assembly process in collaboration with quality control

•   Level 1 attendance for external suppliers

•   Factory acceptance test (FAT) attendance and involvement

•   Participation in module disassembly / transportation preparation process

- Pre-construction activities:

•   Preparing method statements and risk assessments documentation

•   Developing detailed scope of work documentation

•   Creating commissioning programs, scripts, and schedules

•   Supporting program managers during tendering phase

- Construction phase:

•   Managing or supervising the assembly

•   Site management

•   Health & safety coordination

•   On-site quality control

•   On-site commissioning

•   Conducting training sessions

Smartone

Việc triển khai Vertiv OneCore hiệu quả cho phép:

- Quản lý Độ phức tạp của Dự án: Các tùy chọn hợp tác linh hoạt giúp khách hàng quản lý các dự án trung tâm dữ liệu phức tạp theo khả năng và nhu cầu của họ.

- Giảm thiểu Rủi ro: Thông qua kế hoạch tiền thi công toàn diện, các tuyên bố phương pháp chi tiết và đánh giá rủi ro, chúng tôi giúp khách hàng giảm thiểu rủi ro triển khai.

- Đảm bảo Chất lượng: Quy trình kiểm soát chất lượng hai lớp của chúng tôi (cả tại nhà máy và tại công trường) cho phép đạt tiêu chuẩn cao trong suốt quá trình triển khai.

- Tối ưu hóa Nguồn lực: Bằng cách cung cấp dịch vụ quản lý công trường, điều phối H&S và đào tạo giàu kinh nghiệm, khách hàng không cần phải tìm kiếm và quản lý nhiều nhà thầu hoặc phát triển chuyên môn nội bộ.

- Quản lý Tiến độ Dự án: Phương pháp đúc sẵn của chúng tôi với tiến trình giai đoạn rõ ràng từ trước khi bán hàng đến khi vận hành giúp triển khai dự án hiệu quả và giảm thiểu khả năng chậm trễ.

- Tích hợp Kỹ thuật: Bằng cách hợp tác với các chuyên gia triển khai trong giai đoạn thiết kế, chúng tôi giúp ngăn ngừa các vấn đề tiềm ẩn tại chỗ trước khi chúng xảy ra, tích hợp kinh nghiệm thực tế vào các giải pháp thiết kế.

- Chuyển đổi liền mạch: Phương pháp tiếp cận toàn diện của chúng tôi cho phép chuyển đổi suôn sẻ giữa giai đoạn lắp ráp tại nhà máy và giai đoạn triển khai tại chỗ, giảm thiểu những thách thức trong việc phối hợp cho khách hàng.

" Chúng ta không thể thay đổi được hướng gió nhưng có thể điều khiển cánh buồm. " _ Khuyết Danh

👉 Hãy đặt nền móng cho sự hợp tác bằng cách gọi cho tôi
 (Mr Hoàng) Hotline: 0941531889

 Website: VOIMB.COM
sản phẩm khác
ĐẾN VÀ TRẢI NGHIỆM TẠI HỆ THỐNG TRƯNG BÀY SẢN PHẨM
Đội Ngũ Kỹ Thuật Lắp Đặt Đúng Tiêu Chuẩn

VOIMB - Tư vấn tổng thể giải pháp phòng máy chủ.
VOIMB với mong muốn góp phần phát triển kinh tế bằng các sản phẩm chính Hãng với độ bền cao, đáp ứng nhu cầu nguồn điện sạch, giải pháp tối ưu luồng khí lạnh...
Chúng tôi luôn chú ý đến từng yêu cầu, ngân sách của khách hàng để tư vấn giải pháp tiết kiệm và hiệu quả nhất.
TRẢI NGHIỆM SẢN PHẨM TRỰC TIẾP TẠI
Các sản phẩm do VOIMB cung cấp có thời gian bảo hành tối thiểu 12 tháng,
hiệu suất cao, tiết kiệm điện và Tối ưu về giải Pháp
showroom Q.11
28D Tống Văn Trân P. 5, Quận 11, Tp.HCM
Showroom Q.Bình Thạnh
371 Bạch Đằng P.15, Q.Bình Thạnh, Tp.HCM
Showroom Q.10
354 Ngô Gia Tự Phường 4, Quận 10, Tp.HCM
ĐĂNG KÝ NHẬN HỖ TRỢ NHANH
*
Mới đến cũCũ đến mớiGiá tăng dầnGiá giảm dầnTừ A-ZTừ Z-A
GỬI THÔNG TIN Chú ý : (*) Quý khách vui lòng không để trống
ĐĂNG KÝ TƯ VẤN